MARCOVIS FM-X5/PA +Vis TF/Zn
- Through dowel /polyamide + countersunk screw torx /zinc plated, not mounted, for solid and hollow materials.
Applications
- Fixing of cladding and accessories on: solid materials - non-cracked concrete - hollow materials.
Advantages
- All-purpose anchor for solid and hollow materials.
- Transverse mounting.
- To fasten large thicknesses.
- Smooth screwing (low screwing torque).
- Extra-flexible high-quality nylon.
- Highly corrosion resistant in stainless steel version.
- Delivered complete: assembled anchor + screw.
Technical characteristics
With flange |
True |
Installation mode |
hammer laying Installation with torx screwdriving |
Pattern |
Torx |
Supporting material |
Cracked concrete cellular concrete Concrete Hollow brick Hollow concrete block Solid concrete block with prior testing Natural stone with prior testing Solid brick with prior testing |
Product material |
PA6 polyamide + Zinc-plated steel |
Pre-assembled product |
True |
Head shape |
Coutersunked head |
Minimum drilling depth |
80 |
Minimum depth of implementation |
70 |
Load recovery |
138 Kg |
Type of load |
Light load |
Minimum thickness of base material |
120 |
Generic code | d0
(mm)
Support drilling diameter
|
L
(mm)
Length
|
H1
Minimum drilling depth
|
Hnom
Minimum depth of implementation
|
|
360500MARCOVIS FM-X5 TF/Tx30 Zn 8/10x80 | 8 | 80 | 80 | 70 | |
360502MARCOVIS FM-X5 TF/Tx30 Zn 8/30x100 (50) | 8 | 100 | 80 | 70 | |
360504MARCOVIS FM-X5 TF/Tx30 Zn 8/50x120 | 8 | 120 | 80 | 70 | |
360505MARCOVIS FM-X5 TF/Tx30 Zn 8/80x150 | 8 | 150 | 80 | 70 | |
360506MARCOVIS FM-X5 TF/Tx40 Zn 10/15x85 | 10 | 85 | 80 | 70 | |
360507MARCOVIS FM-X5 TF/Tx30 Zn 8/100x170 (50) | 8 | 170 | 80 | 70 | |
360508MARCOVIS FM-X5 TF/Tx40 Zn 10/30x100 | 10 | 100 | 80 | 70 | |
360510MARCOVIS FM-X5 TF/Tx40 Zn 10/45x115 | 10 | 115 | 80 | 70 | |
360512MARCOVIS FM-X5 TF/Tx40 Zn 10/65x135 | 10 | 135 | 80 | 70 | |
360514MARCOVIS FM-X5 TF/Tx40 Zn 10/90x160 | 10 | 160 | 80 | 70 | |
360516MARCOVIS FM-X5 TF/Tx40 Zn 10/130x200 | 10 | 200 | 80 | 70 | |
360518MARCOVIS FM-X5 TF/Tx40 Zn 10/160x230 | 10 | 230 | 80 | 70 |
Pull Out test
ETANCO carries out pull-out tests on site to validate the best solution. Following the tests, a report will be provided to you to justify the maximum resistance value of the anchoring in the support material of your site.
DiscoverIntegrated engineering office
We place our customers at the heart of our priorities to ensure that we listen to them and advise them on a daily basis. Since each application requires different fixing solutions, our design offices are on hand to guide you in your choices. ETANCO will draw up a personalised and adapted calculation note free of charge (according to the regulations in force and the reference documents for each fastener).
DiscoverSoftware Specif Chevilles
Simple, effective and fast, SPECIF determines and calculates the right anchor for your site. Your customised anchor solution.
Discover- In accordance with the ETA 10 0425 anchors MARCOVIS FMX5
Find our technical sheets and declarations of performance in the generic code product page.