LR IT-FIX TAMIS /CFV
- Chemical dowelling system: Screen /polypropylene + threaded rod /composite + nut and washer /inox A2.
Applications
- Intended use: All hollow and solid materials with prior testing until 15kg.
- Fixing of elements attached to the facade in ITE: Light cladding, rainwater downpipes, letterboxes, lighting, etc.
- Thermal break system for fixing elements to buildings with external thermal insulation.
Advantages
- Chemical seal with thermal break system.
- Heat loss coefficient de 0.0010 à 0.0020k/w. 0.0010 to 0.0020k/w.
- Fixing in all substrates: hollow, solid, soft and friable.
- Compatible with wood and metal frames.
- 160x better than steel.
- Ensures continuity in the insulating exterior wall.
- No formation of condensation in the building.
- Quick and easy installation. Ideal for new builds and renovation work. Will not compress insulation. Zero corrosion. Avoids damaging the coating.
Technical characteristics
Thermal conductivity |
0,3 W/MK 0.3 W/MK |
Supporting material |
cellular concrete Hollow brick Hollow concrete block Solid concrete block with prior testing Natural stone with prior testing Solid brick with prior testing |
Product material |
Fiberglass composite |
Length |
330 mm |
Support drilling diameter |
16 mm |
Load recovery |
15 Kg |
Minimum depth of implementation |
130 |
Minimum thickness of base material |
160 |
Outside body diameter |
16 mm |
Generic code | Cond_th
(W/MK)
Thermal conductivity
|
M
Internal diameter
|
L
(mm)
Length
|
Tfix maxi
Maximum thickness of the element to be fixed
|
|
364368LR IT-FIX TAMIS M8/100x280 | 0.3 | M8 | 330 | 100 | |
364369LR IT-FIX TAMIS M8/120x300 | 0.3 | M8 | 330 | 120 | |
364370LR IT-FIX TAMIS M8/140x320 | 0.3 | M8 | 330 | 140 | |
364371LR IT-FIX TAMIS M8/160x340 | 0.3 | M8 | 330 | 160 | |
364372LR IT-FIX TAMIS M8/180x360 | 0.3 | M8 | 330 | 180 | |
364373LR IT-FIX TAMIS M8/200x380 | 0.3 | M8 | 330 | 200 | |
364374LR IT-FIX TAMIS M10/100x290 | 0.3 | M10 | 330 | 100 | |
364375LR IT-FIX TAMIS M10/120x310 | 0.3 | M10 | 330 | 120 | |
364376LR IT-FIX TAMIS M10/140x330 | 0.3 | M10 | 330 | 140 | |
364377LR IT-FIX TAMIS M10/160x350 | 0.3 | M10 | 330 | 160 | |
364378LR IT-FIX TAMIS M10/180x370 | 0.3 | M10 | 330 | 180 | |
364379LR IT-FIX TAMIS M10/200x390 | 0.3 | M10 | 330 | 200 | |
364380LR IT-FIX TAMIS M12/100x300 | 0.3 | M12 | 330 | 100 | |
364381LR IT-FIX TAMIS M12/120x320 | 0.3 | M12 | 330 | 120 | |
364382LR IT-FIX TAMIS M12/140x340 | 0.3 | M12 | 330 | 140 | |
364383LR IT-FIX TAMIS M12/160x360 | 0.3 | M12 | 330 | 160 | |
364384LR IT-FIX TAMIS M12/180x380 | 0.3 | M12 | 330 | 180 | |
364385LR IT-FIX TAMIS M12/200x400 | 0.3 | M12 | 330 | 200 |
Pull Out test
ETANCO carries out pull-out tests on site to validate the best solution. Following the tests, a report will be provided to you to justify the maximum resistance value of the anchoring in the support material of your site.
DiscoverIntegrated engineering office
We place our customers at the heart of our priorities to ensure that we listen to them and advise them on a daily basis. Since each application requires different fixing solutions, our design offices are on hand to guide you in your choices. ETANCO will draw up a personalised and adapted calculation note free of charge (according to the regulations in force and the reference documents for each fastener).