TIGE FILETEE InA2 10x110+Rd+Ecr
Generic code 344960
- Straight cut A2 stainless steel threaded rod M10x110 with unmounted washer and H17 nut, for chemical seal.
Applications
- Intended use: Concrete and solid or hollow materials with prior testing - Applications for heavy loads.
- Fixing the façade insulation brackets (ISOLALU / ISOLCO / KONSOL) to the load-bearing wall.fixing the brackets (SR / SRM / VRM stapled stones) to the load-bearing wall.
- Fixing the legs (SR / SRM / VRM stapled stones) to the supporting wall.
Technical characteristics
Diameter on thread |
10
mm |
Length of the threaded part |
110
mm |
Product material |
A2 Stainless steel |
Length |
110
mm |
Support drilling diameter |
12
mm |
Drive |
17
mm |
Length |
110
mm |
Product material |
A2 Stainless steel |
Outside body diameter |
10
mm |
Maximum thickness of the element to be fixed |
11 |
Minimum drilling depth |
80 |
Required tightening torque |
20
Nm |
Effective anchoring depth |
90 |
Support drilling diameter |
12
mm |
Diameter of the passage hole |
12
mm |
Minimum thickness of base material |
110 |
Maximum thickness of the element to be fixed |
11
mm |
Minimum thickness of base material |
110
mm |
Required tightening torque |
20
Nm |
Diameter of the passage hole |
12
mm |
Effective anchoring depth |
90
mm |
Rod finish |
Straight cut |
Diameter on thread |
10
mm |
Content |
50 threaded rods M10x110 stainless steel A2 +50 washers stainless steel A2 +50 nuts H17 stainless steel A2 not assembled. |
Minimum drilling depth |
80
mm |
Drive |
17
mm |
Designation | Article codes | Color label |
Our program of screws and lacquered accessories offers more than 2000 colors for our roofing / cladding / facade applications. Discover the width of our color palette with our lacquering expertise.
![](/medias/Photo-categorie-service-S1-Essai-arrachement.jpeg?context=bWFzdGVyfGltYWdlc3wxNTgyMDd8aW1hZ2UvanBlZ3xhREV3TDJobVlTODRPREF6TnpFMU5ERTJNRGswTDFCb2IzUnZYMk5oZEdWbmIzSnBaVjl6WlhKMmFXTmxYMU14WDBWemMyRnBYMkZ5Y21GamFHVnRaVzUwfGFjNTMwM2FhY2Y3MjFlZmY5YTc5NmY2MjZkZWFjN2E2YmM2YmU1YWFjMzU1YzgxYThkNTEyYmIxZmUyY2ZlNTI&attachment=true)
Pull Out test
ETANCO carries out pull-out tests on site to validate the best solution. Following the tests, a report will be provided to you to justify the maximum resistance value of the anchoring in the support material of your site.
Discover![](/medias/Photo-categorie-service-S8-Bureau-etudes-integre.jpeg?context=bWFzdGVyfGltYWdlc3wxNDE2ODN8aW1hZ2UvanBlZ3xhRGN4TDJobVpTODRPREF6TnpFMU5qYzRNak00TDFCb2IzUnZYMk5oZEdWbmIzSnBaVjl6WlhKMmFXTmxYMU00WDBKMWNtVmhkVjlsZEhWa1pYTmZhVzUwWldkeVpRfDFjNjI3YTgyMzk2MDM2YWNhMmVhNmRmMTBjZmRhNDI0MTZlNzVmNDBjYTBhODdkMWZlZjY0ZTNlY2EwYTBhYjQ&attachment=true)
Integrated engineering office
We place our customers at the heart of our priorities to ensure that we listen to them and advise them on a daily basis. Since each application requires different fixing solutions, our design offices are on hand to guide you in your choices. ETANCO will draw up a personalised and adapted calculation note free of charge (according to the regulations in force and the reference documents for each fastener).
Discover![](/medias/Photo-categorie-service-S30-Specif-chevillage.jpeg?context=bWFzdGVyfGltYWdlc3wxNzE5NTJ8aW1hZ2UvanBlZ3xhRFl3TDJobVlpODRPREF6TnpFMU56UXpOemMwTDFCb2IzUnZYMk5oZEdWbmIzSnBaVjl6WlhKMmFXTmxYMU16TUY5VGNHVmphV1pmWTJobGRtbHNiR0ZuWlF8OTU5NmQyOThmNWIyMDZkNDY2NGZmYWU4ZjU2OWU2MDkyMWIwOGM2MWFkYmVjOWQ3YjY5MTA1ZGQwMWIzZTE4Ng&attachment=true)
Software Specif Chevilles
Simple, effective and fast, SPECIF determines and calculates the right anchor for your site. Your customised anchor solution.
Discover