Applications
- Pre-mounted system for fastening waterproofing (bitumen covering with semi-rigid insulation) on perforated or punctured steel roofing panels painted on the underside.
Advantages
- This single-piece pre-assembled system increases productivity when fitting the sealing on the perforated or punctured steel roofing panel.
- Ensures "solid on pitch".
- Prevents perforation of the waterproof coating.
- Prevents crushing of the insulation.
- Rivet end on the underside: Aesthetic and non blunt.
- The lacquered rivet body is finished and discreet if the underside of the substrate is visible.
- No loosening possible.
- Please contact us for other lengths.
Technical characteristics
Content |
Standard non-waterproof rivet + Spacer + Spreader washer pre-assembled. |
Laquering |
Painted body |
Type of installation of waterproofing |
Traditional mechanical installation |
Solid in step |
True |
Waterproofing complex |
Semi-rigid insulation Bitumen |
Type of steel sheet |
Perforated or punctured metal sheet |
Resistance to corrosion |
15 Kesternich cycles |
External diameter of the spacer |
8 mm |
Spacer material |
Aluminum |
Thickness |
0,8 mm |
Pre-drilling |
With pre-drilling |
5 features on 11
12 generic codes
Filter:
Generic code | LE
(mm)
Spacer length
|
CE
Waterproofing complex
|
TB
Type of steel sheet
|
Df
(mm)
Diameter on thread
|
L
(mm)
Length
|
CS Maxi
(mm)
Maximum clamping capacity
|
|
271028RER Al/Ac 5x170+RDØ40AZ+Ent.148 |
148 | Bitumen,Semi-rigid insulation | Perforated or punctured metal sheet | 5 | 170 | 150 | |
271033RER Al/Ac 5x180+RDØ40AZ+Ent.158 |
158 | Semi-rigid insulation,Bitumen | Perforated or punctured metal sheet | 5 | 180 | 160 | |
271038RER Al/Ac 5x190+RDØ40AZ+Ent.168 |
168 | Bitumen,Semi-rigid insulation | Perforated or punctured metal sheet | 5 | 190 | 170 | |
271041RER Al/Ac 4.8x55+RDØ40AZ+Ent38 |
38 | Semi-rigid insulation,Bitumen | Perforated or punctured metal sheet | 4.8 | 55 | 40 | |
271046RER Al/Ac 4.8x60+RDØ40AZ+Ent43 |
43 | Semi-rigid insulation,Bitumen | Perforated or punctured metal sheet | 4.8 | 60 | 45 | |
271051RER Al/Ac 4.8x65+RDØ40AZ+Ent48 |
48 | Bitumen,Semi-rigid insulation | Perforated or punctured metal sheet | 4.8 | 65 | 50 | |
271061RER Al/Ac 4.8x75+RDØ40AZ+Ent58 |
58 | Bitumen,Semi-rigid insulation | Perforated or punctured metal sheet | 4.8 | 75 | 60 | |
271066RER Al/Ac 4.8x80+RDØ40AZ+Ent63 |
63 | Bitumen,Semi-rigid insulation | Perforated or punctured metal sheet | 4.8 | 80 | 65 | |
271071RER Al/Ac 4.8x85+RDØ40AZ+Ent68 |
68 | Semi-rigid insulation,Bitumen | Perforated or punctured metal sheet | 4.8 | 85 | 70 | |
271101RER Al/Ac 4.8x120+RDØ40AZ+Ent98 |
98 | Bitumen,Semi-rigid insulation | Perforated or punctured metal sheet | 4.8 | 120 | 100 | |
271121RER Al/Ac4.8x140+RDØ40AZ+Ent118 |
118 | Semi-rigid insulation,Bitumen | Perforated or punctured metal sheet | 4.8 | 140 | 120 | |
271131RER Al/Ac4.8x150+RDØ40AZ+Ent128 |
128 | Bitumen,Semi-rigid insulation | Perforated or punctured metal sheet | 4.8 | 150 | 130 |
generic codes on
- In accordance with DTU 43. 3: Roofing work with ribbed steel sheets with waterproof coatings.
- Conventional test method for step strengh characteristic for fasteners according to the standard NF P 30-317.
Interested in this product ?
Contact us