Applications
- Pre-mounted system for fastening waterproofing (bitumen covering with semi-rigid insulation) on perforated or punctured steel roofing panels.
Advantages
- This single-piece pre-assembled system increases productivity when fitting the sealing on the perforated or punctured steel roofing panel.
- Ensures "solid to the step".
- Prevents perforation of the waterproof coating.
- Prevents crushing of the insulation.
- Rivet end on the underside: Aesthetic and non blunt.
- The lacquered rivet body is finished and discreet if the underside of the substrate is visible.
- No loosening.
- Please contact us for other lengths.
Technical characteristics
Content |
Standard non-waterproof rivet + Spacer + Pre-assembled distribution plate. |
Laquering |
Natural body |
Type of installation of waterproofing |
Traditional mechanical installation |
Solid in step |
True |
Waterproofing complex |
Semi-rigid insulation Bitumen |
Type of steel sheet |
Perforated or punctured metal sheet |
Resistance to corrosion |
15 Kesternich cycles |
External diameter of the spacer |
8 mm |
Spacer material |
Aluminum |
Width |
40 mm |
Accessory's length |
40 mm |
Thickness |
0,8 mm |
Pre-drilling |
With pre-drilling |
5 features on 13
8 generic codes
Filter:
Generic code | LE
(mm)
Spacer length
|
CE
Waterproofing complex
|
TB
Type of steel sheet
|
Df
(mm)
Diameter on thread
|
L
(mm)
Length
|
Ls
(mm)
Accessory's length
|
CS Maxi
(mm)
Maximum clamping capacity
|
|
272040PER Al/Ac 4.8x55+P40x40AZ+Ent36 | 36 | Semi-rigid insulation,Bitumen | Perforated or punctured metal sheet | 4.8 | 55 | 40 | 40 | |
272050PER Al/Ac 4.8x65+P40x40AZ+Ent46 | 46 | Semi-rigid insulation,Bitumen | Perforated or punctured metal sheet | 4.8 | 65 | 40 | 50 | |
272060PER Al/Ac 4.8x75+P40x40AZ+Ent56 | 56 | Semi-rigid insulation,Bitumen | Perforated or punctured metal sheet | 4.8 | 75 | 40 | 60 | |
272080PER Al/Ac 4.8x95+P40x40AZ+Ent76 | 76 | Bitumen,Semi-rigid insulation | Perforated or punctured metal sheet | 4.8 | 95 | 40 | 80 | |
272100PER Al/Ac 4.8x120+P40x40AZ+Ent96 | 96 | Semi-rigid insulation,Bitumen | Perforated or punctured metal sheet | 4.8 | 120 | 40 | 100 | |
272132PER Al/Ac 5x170+P40x40AZ+Ent 148 | 148 | Bitumen,Semi-rigid insulation | Perforated or punctured metal sheet | 5 | 170 | 40 | 150 | |
272134PER Al/Ac 5x180+P40x40AZ+Ent.158 | 158 | Bitumen,Semi-rigid insulation | Perforated or punctured metal sheet | 5 | 180 | 40 | 160 | |
272136PER Al/Ac 5x190+P40x40AZ+Ent.168 | 168 | Semi-rigid insulation,Bitumen | Perforated or punctured metal sheet | 5 | 190 | 40 | 170 |
generic codes on
- In accordance with DTU 43. 3: Roofing work with ribbed steel sheets with waterproof coatings.
- Conventional test method for step strengh characteristic for fasteners according to the standard NF P 30-317.