LR IT-FIX SHUTTER Ø120 /PA
- Mechanical dowelling system: Thermal bridge spacer Ø120 / polyamide.
Applications
- Intended use: All hollow and solid materials with prior testing until 80kg.
- Fixing of façade components in ITE & ITI: sliding and swinging shutters, adjustable sunshades, rainwater downpipes, satellite dishes, heat pumps, air conditioners, etc.
- Thermal break system for fixing elements to buildings with external thermal insulation.
Advantages
- Heat loss coefficient = 0. 0033 until 0. 097 w/k.
- Fixing in all substrates: hollow, solid, soft and friable (depending on the type of plug used).
- Ensures continuity in the insulating exterior wall.
- Eliminates all intermittent thermal breaks.
- No formation of condensation in the building.
- Easy and quick to install before or after thermal insulation. Ideal for new build or renovation. Does not compress the insulation. Zero corrosion. Preserves the plaster.
Technical characteristics
Thermal conductivity |
0,3 W/MK |
Supporting material |
Cellular concrete Concrete Hollow brick Solid brick Natural stone Hollow concrete block Solid concrete block |
Product material |
Fiberglass composite |
Maximum thickness of the element to be fixed |
100 120 140 80 |
Content |
LR IT-Fix SHUTTER Ø120 composition: 1 - Force-feeding network. 2 - Ø120x100mm connecting spacer 90mm center distance - Polyamide. 3 - Pair of anchors (not supplied). LR IT-Fix SHUTTER Ø120 composition: 1 - Force-feeding network. 2 - Ø120x120mm connecting spacer - Polyamide. 3 - Pair of anchors (not supplied). LR IT-Fix SHUTTER Ø120 composition: 1 - Force-feeding network. 2 - Ø120x120mm connecting spacer 90mm center distance - Polyamide. 3 - Pair of anchors (not supplied). LR IT-Fix SHUTTER Ø120 composition: 1 - Force-feeding network. 2 - Ø120x140mm connecting spacer 90mm center distance - Polyamide. 3 - Pair of anchors (not supplied). LR IT-Fix SHUTTER Ø120 composition: 1 - Force-feeding network. 2 - Ø120x160mm connecting spacer 90mm center distance - Polyamide. 3 - Pair of anchors (not supplied). |
Load recovery |
900 Kg |
Outside body diameter |
120 mm |
Generic code | Cond_th
(W/MK)
Thermal conductivity
|
L
(mm)
Length
|
Tfix maxi
Maximum thickness of the element to be fixed
|
|
364323LR IT-FIX SHUTTER 120x80 (Entraxe.90mm) | 0.3 | 100 | 80 | |
364324LR IT-FIX SHUTTER 120x100 (Ss entraxe) | 0.3 | 100 | ||
364325LR IT-FIX SHUTTER 120x100 (Entraxe.90mm) | 0.3 | 120 | 100 | |
364326LR IT-FIX SHUTTER 120x120 (Entraxe.90mm) | 0.3 | 140 | 120 | |
364327LR IT-FIX SHUTTER 120x140 (Entraxe.90mm) | 0.3 | 160 | 140 |

Pull Out test
ETANCO carries out pull-out tests on site to validate the best solution. Following the tests, a report will be provided to you to justify the maximum resistance value of the anchoring in the support material of your site.
Discover
Integrated engineering office
We place our customers at the heart of our priorities to ensure that we listen to them and advise them on a daily basis. Since each application requires different fixing solutions, our design offices are on hand to guide you in your choices. ETANCO will draw up a personalised and adapted calculation note free of charge (according to the regulations in force and the reference documents for each fastener).
Discover
Software Specif Chevilles
Simple, effective and fast, SPECIF determines and calculates the right anchor for your site. Your customised anchor solution.
Discover- In accordance with the standard NF EN ISO 10211.