ISOPLUS T60 /PP +Vis /Zn
- Ø8 /polypropylene dowel with wide head Ø60 mounted with nail screw /zinc plated, for rigid insulation.
Applications
- Intended use: All hollow and solid materials (1) with prior testing.
- Fixing rigid and semi-rigid insulation to the façade.
Advantages
- Controlled deformation anchor.
- Heat loss coefficient = 0 W/K.
Technical characteristics
Load recovery |
43 Kg |
With flange |
True |
Installation mode |
Hammer laying Installation with torx screwdriving |
Type of flange |
Large |
Flange head diameter |
60 mm |
Supporting material |
Cellular concrete Concrete Hollow brick Solid brick Solid concrete block Hollow concrete block with prior testing Natural stone with prior testing |
Product material |
Polypropylene + Zinc-plated steel |
Support drilling diameter |
8 mm |
Maximum thickness of the element to be fixed |
110 130 150 170 190 210 230 250 70 90 |
Minimum drilling depth |
75 |
Minimum depth of implementation |
50 80 |
Content |
200 dowels Ø8/110x160 polypropylene +200 unassembled galvanised screws. 200 dowels Ø8/130x180 polypropylene +200 unmounted zinc-plated screws. 200 dowels Ø8/150x200 polypropylene +200 unassembled zinc-plated screws. 200 dowels Ø8/170x220 polypropylene +200 zinc-plated screws, not mounted. 200 dowels Ø8/190x240 polypropylene +200 zinc-plated screws not mounted. 200 dowels Ø8/210x260 polypropylene +200 unassembled galvanised screws. 200 dowels Ø8/230x280 polypropylene +200 unassembled galvanised screws. 200 dowels Ø8/250x300 polypropylene +200 zinc-plated screws, not mounted. 200 dowels Ø8/70x120 polypropylene +200 unassembled zinc-plated screws. 200 dowels Ø8/90x140 polypropylene +200 zinc-plated screws not mounted. |
Outside body diameter |
8 mm |
Minimum thickness of base material |
100 |
Generic code | Tfix maxi
Maximum thickness of the element to be fixed
|
L
(mm)
Length
|
H1
Minimum drilling depth
|
Hnom
Minimum depth of implementation
|
|
357120ISOPLUS 8/70x120 | 70 | 120 | 75 | 80 | |
357140ISOPLUS 8/90x140 | 90 | 140 | 75 | 50 | |
357160ISOPLUS 8/110x160 | 110 | 160 | 75 | 50 | |
357180ISOPLUS 8/130x180 | 130 | 180 | 75 | 50 | |
357200ISOPLUS 8/150x200 | 150 | 200 | 75 | 50 | |
357220ISOPLUS 8/170x220 | 170 | 220 | 75 | 50 | |
357240ISOPLUS 8/190x240 | 190 | 240 | 75 | 50 | |
357260ISOPLUS 8/210x260 | 210 | 260 | 75 | 50 | |
357280ISOPLUS 8/230x280 | 230 | 280 | 75 | 50 | |
357300ISOPLUS 8/250x300 | 250 | 300 | 75 | 50 |

Pull Out test
ETANCO carries out pull-out tests on site to validate the best solution. Following the tests, a report will be provided to you to justify the maximum resistance value of the anchoring in the support material of your site.
Discover
Integrated engineering office
We place our customers at the heart of our priorities to ensure that we listen to them and advise them on a daily basis. Since each application requires different fixing solutions, our design offices are on hand to guide you in your choices. ETANCO will draw up a personalised and adapted calculation note free of charge (according to the regulations in force and the reference documents for each fastener).
Discover
Software Specif Chevilles
Simple, effective and fast, SPECIF determines and calculates the right anchor for your site. Your customised anchor solution.
Discover- In accordance with the ETA 22 0294 anchors ISOPLUS
Find our technical sheets and declarations of performance in the generic code product page.