HEMA DF /Zn
- Hammer-in dowel with threaded sleeve / zinc-plated with Hu nut, special for aerated concrete.
Applications
- Intended use: Cellular concrete (without starter hole) - Permanent fastening.
Advantages
- Pre-assembled drive anchor to be hammered in.
- Quick to lay, without pre-drilling.
- Non-removable fastening (DS version).
- Fire resistant.
Technical characteristics
Installation mode |
hammer laying Installation with hexagonal screwdriving wrench tightened |
Supporting material |
cellular concrete |
Product material |
Zinc plated steel |
Pre-assembled product |
True |
Load recovery |
41 Kg |
Type of load |
Light load |
Generic code | L
(mm)
Length
|
Hnom
Minimum depth of implementation
|
|
343230HEMA DF 6/10x60 | 60 | 50 | |
343240HEMA DF 6/40x90 | 90 | 50 | |
343250HEMA DF 6/80x130 | 130 | 50 | |
343275HEMA DF 8/10x90 | 90 | 87 | |
343290HEMA DF 8/25x115 | 115 | 87 | |
343295HEMA DF 8/45x130 | 130 | 87 |
Pull Out test
ETANCO carries out pull-out tests on site to validate the best solution. Following the tests, a report will be provided to you to justify the maximum resistance value of the anchoring in the support material of your site.
DiscoverIntegrated engineering office
We place our customers at the heart of our priorities to ensure that we listen to them and advise them on a daily basis. Since each application requires different fixing solutions, our design offices are on hand to guide you in your choices. ETANCO will draw up a personalised and adapted calculation note free of charge (according to the regulations in force and the reference documents for each fastener).
DiscoverSoftware Specif Chevilles
Simple, effective and fast, SPECIF determines and calculates the right anchor for your site. Your customised anchor solution.
Discover- Benefit from a test report VERITAS dlc 78743910 anchors HEMA. Except articles codes (343230, 343240, 343295, 343290 )
Find our technical sheets and declarations of performance in the generic code product page.