Technical characteristics
Type of the screw tip |
Countersink sharp point (233 G) |
With flange |
True |
Flange head diameter |
16
mm |
Type of thread |
Single thread |
Pre-drilling |
With pre-drilling on steel only |
Anchoring depth |
30
mm |
Product material |
2C Supracoat coated steel |
Drilling capacity maxi |
2 x 0.75 |
Head shape |
Hex. Head |
Support drilling diameter |
5.95
mm |
pattern hexagonal |
TH 12 |
Material of the screw head |
Polyamid colored |
Laquering |
Painted head |
With washer/ seal |
True |
Type of the washer |
Vulca washer |
Material of the washer/ Seal |
Alu/ EPDM |
Outside diameter of the washer |
14
mm |
Thickness of the flange |
3.8
mm |
Resistance to corrosion |
15 Kesternich cycles |
Guaranteed against corrosion for 20 years |
True |
Installation mode |
Installation with hexagonal screwdriving |
Supporting material |
Steel Wood |
Diameter on thread |
6.5
mm |
Thread pitch |
2.54
mm |
Length |
50
mm |
Head height |
9.3
mm |
Minimum clamping capacity |
0
mm |
Maximum clamping capacity |
15
mm |
Maximum assembly capacity |
31
mm |
Length of the threaded part |
50
mm |
Sold by bag of 100 pieces
Designation | Article codes | Color label | Quantity |
Our program of screws and lacquered accessories offers more than 2000 colors for our roofing / cladding / facade applications. Discover the width of our color palette with our lacquering expertise.
- Wood anchoring depth for cladding/façade applications: 30 mm min. Wood anchoring depth for roofing/sealing applications: 50 mm min. On a steel support, the max. CA should be the selection criterion. Used with a HH12 screwdriving socket.
- In accordance with DTU 40. 35: Roofing work using ribbed plates - Coated STEEL sheets.
- In accordance with DTU 40. 36: Roofing work using ribbed plates - Coated ALUMINUM sheets.