EQUERRE ISOLCO-3000P2 M10 Lg.90mm
Generic code 367135
- Perforated bracket for façade 50x90x60x2.5 Z450 galvanised steel for M10 anchor.
 
Applications
- Façade insulation bracket for the vertical fastening of wood rafters.
 - Facade insulation bracket for verticale fastening of steel profiles.
 - Enables wood rafters to be connected to the main structure on all building types, whether new or undergoing renovation.
 - Enables steel profiles to be connected to the main structure on all building types, whether new or undergoing renovation.
 - Adaptable to different types of cladding: Fibre-cement, HPL, terracotta, wood, ceramic, metal and alloy, etc.
 
Advantages
- Enable profiles or timber rafters to be connected to the main structure on all types of new or renovation construction projects.
 - Adapt to all types of facin materials: fibres-cement, HPL, terracotta, wood, ceramics, stone, metals and alloys, bitumen shingles, aggregate concrete and more.
 - Oblong hole for perpendicular adjustment.
 - Compatible with the atmosphere of buildings located less than 3 km from the coast (excluding conditions of direct attack by sea water and spray).
 
Technical characteristics
| Length | 
								90
										 mm | 
						
| System | 
								Wood frame & Steel frame | 
						
| Thickness | 
								2.5
										 mm | 
						
| Product material | 
								Z450 Galvanized steel | 
						
| Width | 
								50
										 mm | 
						
| Depth | 
								50
										 mm | 
						
| Height | 
								60
										 mm | 
						
| Section in mm | 
								50x90x60x2.5 | 
						
Sold by bag of 200 pieces
| Designation | Article codes | Color label | Quantity | 
Our program of screws and lacquered accessories offers more than 2000 colors for our roofing / cladding / facade applications. Discover the width of our color palette with our lacquering expertise.
- M8 anchoring compatible in seismic zone C1. M10 anchoring compatible in seismic zones C1 and C2, and compatible with the MARCOVIS FM-X5 TH Ø 10 anchors.
 
- In accordance with CSTB 3316 specifications: Timber frame and thermal insulation of cladding with AT.
 - In compliance with CSTB 3194 specifications: Metal frame and thermal insulation of cladding with AT.
 - In accordance with DTU 45. 4: External thermal insulation systems in cladding with ventilated air gap.
 
- 
							
								
Technical Data Sheet ISOLCO 3000 P2 M8 BRACKET STAINLESS STEELTechnical datasheetsThis document is reserved for our connected customers,
log in or create an account to download it. - 
							
								
Drawings DXF ISOLCO 3000P2 M10Drawings 2DThis document is reserved for our connected customers,
log in or create an account to download it.