RIVCOLOR NON WATERPROOF CEL Al/In
- Non-sealing rivet /aluminium with extra-wide lacquered collar - mandrel /stainless steel A2.
Applications
- Fixing of facade cladding products pre-drilled colored plans on metal frame, compliant with most technical notices.
Technical characteristics
Installation mode |
Riveting |
Laquering |
Painted flange head |
Type of flange |
Extra- Large |
Support drilling diameter |
5,2 mm 5.2 mm |
Flange head diameter |
16 mm |
Generic code | L
(mm)
Length
|
dw
(mm)
Flange head diameter
|
S mini
(mm)
Minimum nominal grip thickness
|
S maxi
(mm)
Maximum nominal grip thickness
|
|
270564RIVCOLOR Al/In N.E 4.8x16 CEL |
16 | 16 | 10 | 12 | |
270566RIVCOLOR Al/In N.E 4.8x18 CEL |
18 | 16 | 12 | 14 | |
276943RIVCOLOR Al/In N.E. 5x16 CEL16 |
16 | 16 | 8 | 12 | |
276953RIVCOLOR Al/InA2 N.E. 5x12 CEL1612 |
16 |
4 |
8 |
|
|
276955RIVCOLOR Al/InA2 N.E. 5x16 CEL1616 |
16 |
8 |
12 |
|
|
276957RIVCOLOR Al/InA2 N.E. 5x18 CEL1618 |
16 |
9.5 |
13.5 |
|
|
276959RIVCOLOR Al/InA2 N.E. 5x22 CEL16 |
22 | 16 | 12.5 | 16.5 | |
276961RIVCOLOR AL/INA4 4.8x12 CEL 16 |
12 | 16 | 6 | 8 |

lacquering
Discover

Integrated engineering office
We place our customers at the heart of our priorities to ensure that we listen to them and advise them on a daily basis. Since each application requires different fixing solutions, our design offices are on hand to guide you in your choices. ETANCO will draw up a personalised and adapted calculation note free of charge (according to the regulations in force and the reference documents for each fastener).
Discover- In accordance with DTU 45. 4: External thermal insulation systems in cladding with ventilated air gap.