Equerre ISOLALU+ LR80+Câle
- Perforated façade bracket with LR80 clamp in lengths from 60 to 300 mm made of aluminium 6063 T66 for vertical installation with THERMOSTOP ISOLALU+ cable to reduce thermal bridges.
Interested in this product ? Contact us
Applications
- Connecting aluminium vertical profiles to the support wall on all building types, whether new or undergoing renovation.
- Ideal for fastening flat panels >12 kg, ceramic plates, shingles and terracotta, stone, etc.
Advantages
- High resistance characteristics mean the number of brackets per m² can be reduced, thus reducing the installation time.
- Internal clips to position the profiles and enable compatibility with omega or tube profiles.
- Bracket with fixed point and expandable point.
- Possibility to correct a tilt of 2 cm from the perpendicular with the same length of bracket.
- Earthquake-compliant: test report no. MRF 18 26073913 B (HPL panels).
- Pre-mounted insulating wedge to reduce thermal breaks.
Technical characteristics
System |
Aluminum framework |
Content |
0 |
Product material |
Aluminum 6063 T66 + Polyamide PA06 |
Height |
80 mm |
Section in mm |
40.0:mm mm 50.0:mm mm |
14 generic codes
Filter:
Generic code | L
(mm)
Length
|
Dn Maxi
(mm)
Maximum distance from the outdoor nude
|
Dn Mini
(mm)
Minimum distance from the outdoor nude
|
|
610100EQUERRE ISOLALU+ LR80 Lg.40mm+THERMOST. | 40 | 70 | 70 | |
610102EQUERRE ISOLALU+ LR80 Lg.60mm+THERMOST. | 60 | 90 | 90 | |
610104EQUERRE ISOLALU+ LR80 Lg.80mm+THERMOST. | 80 | 110 | 90 | |
610106EQUERRE ISOLALU+ LR80 Lg100mm+THERMOST. | 100 | 130 | 110 | |
610108EQUERRE ISOLALU+ LR80 Lg120mm+THERMOST. | 120 | 150 | 130 | |
610110EQUERRE ISOLALU+ LR80 Lg140mm+THERMOST. | 140 | 170 | 150 | |
610112EQUERRE ISOLALU+ LR80 Lg160mm+THERMOST. | 160 | 190 | 170 | |
610114EQUERRE ISOLALU+ LR80 Lg180mm+THERMOST. | 180 | 210 | 190 | |
610116EQUERRE ISOLALU+ LR80 Lg200mm+THERMOST. | 200 | 230 | 210 | |
610118EQUERRE ISOLALU+ LR80 Lg220mm+THERMOST. | 220 | 250 | 230 | |
610120EQUERRE ISOLALU+ LR80 Lg240mm+THERMOST. | 240 | 270 | 250 | |
610122EQUERRE ISOLALU+ LR80 Lg260mm+THERMOST. | 260 | 290 | 270 | |
610124EQUERRE ISOLALU+ LR80 Lg280mm+THERMOST. | 280 | 310 | 290 | |
610126EQUERRE ISOLALU+ LR80 Lg300mm+THERMOST. | 300 | 330 | 310 |
generic codes on
- In compliance with CSTB 3194 specifications: Metal frame and thermal insulation of cladding with AT.
- In accordance with DTU 45. 4: External thermal insulation systems in cladding with ventilated air gap.
Interested in this product ?
Contact us