ETANCOPLAST HP4L Ø40+ISODRILL
Interested in this product ? Contact us
Applications
- Thermal break system for fastening waterproofing (bitumen covering with semi-rigid or rigid insulation) on solid steel roofing panels, thickness 0.75 to 2x10/10th mm.Adapted to buildings with high and very high hygrometry.
Advantages
- This one-screw pre-assembled system, which can connect to the ANDYPLAST HP installation tool or installation rod, increases productivity when fitting sealing on steel roofing panels.
- Ensures thermal bridge break.
- Prevents perforation of the waterproof coating.
- Reduces screw corrosion.
- Facilitates penetration of different sealing complexes + insulation.
- Reduces the heat transfer coefficient fivefold.
- Vapour permeance measurement
- CSTB test report no. CPM / 03-0059 bis
Technical characteristics
Head shape |
Bugle head |
Pattern Philips |
Phillips 2 |
Type of installation of waterproofing |
Traditional mechanical installation |
Pattern |
Phillips (Ph) |
Waterproofing complex |
Solid insulation Semi-rigid insulation Bitumen Synthetic insulation |
Type of steel sheet |
Full Steel sheet support |
Diameter of the head |
8,5 mm 8.5 mm |
Drilling capacity maxi |
2 x 1 |
Drilling capacity mini |
0.75 |
Resistance to corrosion |
30 Kesternich cycles |
Diameter on thread |
4,8 mm |
External diameter of the spacer |
13,05 mm |
Screw material |
Bi-metal (A4 stainless steel / Steel) |
Spacer material |
PA6 Polyamide |
Width |
40 mm |
Pre-drilling |
Without pre-drilling |
5 features on 16
1 generic code
Filter:
Generic code | CE
Waterproofing complex
|
TB
Type of steel sheet
|
LF
(mm)
Barrel length
|
CP maxi
Drilling capacity maxi
|
Df
(mm)
Diameter on thread
|
L
(mm)
Length
|
Ls
(mm)
Accessory's length
|
CS Maxi
(mm)
Maximum clamping capacity
|
|
237060ETANCOPLAST HP4L 82X40+ISODRILLTT ISOL60 | Synthetic insulation,Semi-rigid insulation,Solid insulation | Full Steel sheet support | 50 | 2 x 1 | 4.8 | 82 | 60 | 60 |
generic codes on
- Evaluation of unscrewing resistance according to the standard NF P 30-317
- Conventional test method for step strengh characteristic for fasteners according to the standard NF P 30-317
Interested in this product ?